公司基本資料信息
|
mso-hansi-font-family:"Times New Roman"">一、概述:?
mso-hansi-font-family:"Times New Roman"">《通用硅酸鹽水泥》新標(biāo)準(zhǔn)于2007 "Times New Roman"">年發(fā)布實(shí)施,該標(biāo)準(zhǔn)將代替GB175 "Times New Roman"">、GB1344 "Times New Roman"">、GB12958 "Times New Roman"">三個標(biāo)準(zhǔn)?!锻ㄓ霉杷猁}水泥》新標(biāo)準(zhǔn)規(guī)定了氯離子含量不大于0.06% "Times New Roman"">的強(qiáng)制性條款,對此我公司研發(fā)生產(chǎn)了CCL "Times New Roman"">-5型氯離子分析儀,以滿足新標(biāo)準(zhǔn)的要求。??
mso-hansi-font-family:"Times New Roman"">二、水泥氯離子含量分析測定儀主要特點(diǎn):
1、分析速度快,單個樣品測定在10 mso-hansi-font-family:"Times New Roman"">分鐘內(nèi)完成。
2、分析精度高、分析結(jié)果偏差小于標(biāo)準(zhǔn)要求的誤差。
3、應(yīng)用范圍廣,可用于水泥成品、半成品及原料的測定, "Times New Roman"">也可用于水泥,砼無外加劑的測定。
4、也可用于水泥及其它原料中氯的測定。
mso-hansi-font-family:"Times New Roman"">三、技術(shù)參數(shù):
1、電源:AC220V
2、加熱功率:1000W
3、氣泵功率:12W
4、控溫精度:±0.2%
5、計時精度:±0.1%
6、蒸餾時間:10-15min
7、溫度設(shè)定:250-260℃
8、重量:25KG
mso-hansi-font-family:"Times New Roman"">四、水泥氯離子含量分析測定儀配件包括:
mso-hansi-font-family:"Times New Roman"">水泥氯含量對比樣品1 "Times New Roman"">瓶、硝酸貢1瓶、二苯偶氮碳酰肼指示劑1 mso-hansi-font-family:"Times New Roman"">瓶、蛇形冷凝管2 "Times New Roman"">支、洗氣瓶2個、石英管4 mso-hansi-font-family:"Times New Roman"">支。?? 附:水泥原料中氯離子分析儀的化學(xué)分析方法?
1、適用范圍:
mso-hansi-font-family:"Times New Roman"">本標(biāo)準(zhǔn)規(guī)定了磷酸蒸餾—汞鹽滴定法測定水泥原料中氯離子的化學(xué)分析方法。 "Times New Roman"">本標(biāo)準(zhǔn)適用于水泥原料及指定采用本標(biāo)準(zhǔn)的其它材料。
2、規(guī)范性引用文件:
mso-hansi-font-family:"Times New Roman"">下列文件中的條款通過本標(biāo)準(zhǔn)的引用而成為本標(biāo)準(zhǔn)的條款。凡是注日期的引用文件,其隨后所有的修改單(不包括勘誤的內(nèi)容)或修訂版均不適用于本標(biāo)準(zhǔn),然而,鼓勵根據(jù)本標(biāo)準(zhǔn)達(dá)成協(xié)議的各方研究是否可使用這些文件的最新版本。凡是不注日期的引用文件,其最新版本適用于本標(biāo)準(zhǔn)。? GB/T2007.1 "Times New Roman"">散裝礦產(chǎn)品取樣、制樣通則、手工取樣 GB/T6682 "Times New Roman"">分析實(shí)驗(yàn)室用水規(guī)格和試驗(yàn)方法
3、試驗(yàn)的基本要求:
3.1 試驗(yàn)次數(shù):每項(xiàng)測定的試驗(yàn)次數(shù)規(guī)定為兩次,用兩次試驗(yàn)平均值表示測定結(jié)果。
3.2 質(zhì)量、體積、滴定度和結(jié)果的表示 "Times New Roman"">用“克(g) "Times New Roman"">”表示質(zhì)量,精確至0.0001g "Times New Roman"">。滴定管體積用“毫升(ml "Times New Roman"">)”表示,精確至0.05ml "Times New Roman"">。滴定度單位用“毫克每毫升(mg/ml "Times New Roman"">)”表示,滴定度修約后保留有效數(shù)字三位。
3.3 空白試驗(yàn):使用相同量的試劑,不加入試樣,按照相同的測定步驟進(jìn)行試驗(yàn),計算時從測定結(jié)果中扣除空白試驗(yàn)值。
4、方法提要:
mso-hansi-font-family:"Times New Roman"">用規(guī)定的蒸餾裝置在250 "Times New Roman"">℃~260℃溫度條件下,以過氧化氫和磷酸分解試樣,以凈化空氣做載體,進(jìn)行蒸餾分離氯離子,用稀硝酸作吸收液,蒸餾10min-15min后,用乙醇吹洗冷凝管及其下端于錐形瓶內(nèi),乙醇的加入量占75% mso-hansi-font-family:"Times New Roman"">(體積分?jǐn)?shù))以上。在PH3.5 "Times New Roman"">左右,以二苯偶氮碳酰肼為指示劑,用硝酸汞標(biāo)準(zhǔn)滴定溶液進(jìn)行滴定。
5、水泥氯離子含量分析測定儀試劑和材料:
mso-hansi-font-family:"Times New Roman"">除另有說明外,所用試劑應(yīng)不低于分析純。用于標(biāo)定與配制標(biāo)準(zhǔn)溶液的試劑應(yīng)為基準(zhǔn)試劑。所用水應(yīng)符合GB/T6682中規(guī)定的三級水要求。? "Times New Roman"">本標(biāo)準(zhǔn)所列市售濃液體試劑的密度指20 "Times New Roman"">℃的密度,單位為克每立方厘米(g/cm3 "Times New Roman"">)。
5.1硝酸(HNO mso-hansi-font-family:"Times New Roman"">3),ρ=1.39g/cm "Times New Roman"">3~1.41g/cm "Times New Roman"">3,65%~68% mso-hansi-font-family:"Times New Roman"">(質(zhì)量分?jǐn)?shù))。
5.2 磷酸(H mso-hansi-font-family:"Times New Roman"">3PO "Times New Roman"">4),85%(質(zhì)量分?jǐn)?shù))。
5.3 乙醇(C mso-hansi-font-family:"Times New Roman"">2H "Times New Roman"">5OH),95% mso-hansi-font-family:"Times New Roman"">(體積分?jǐn)?shù))或無水乙醇。
5.4 過氧化氫(H mso-hansi-font-family:"Times New Roman"">2O "Times New Roman"">2),30%(質(zhì)量分?jǐn)?shù))。?
5.5 氫氧化納(NaOH mso-hansi-font-family:"Times New Roman"">)溶液 [C "Times New Roman"">(NaOH) =0.5mol/L] 將2g mso-hansi-font-family:"Times New Roman"">氫氧化鈉溶于100mL "Times New Roman"">水中。
5.6 硝酸溶液[C mso-hansi-font-family:"Times New Roman"">(HNO3 "Times New Roman"">)= 0.5mol/L] "Times New Roman"">取3mL硝酸(5.1 mso-hansi-font-family:"Times New Roman"">),用水稀釋至100mL "Times New Roman"">。
5.7 氯離子標(biāo)準(zhǔn)溶液? "Times New Roman"">準(zhǔn)確稱取0.3297g "Times New Roman"">已在105℃-110 mso-hansi-font-family:"Times New Roman"">℃烘過2h "Times New Roman"">的氯化鈉,溶于少量水中,然后移入1L "Times New Roman"">容量瓶中,用水稀釋至標(biāo)線,搖勻。此溶液1mL "Times New Roman"">含0.2mg氯離子。 "Times New Roman"">吸取上述溶液50.00ml "Times New Roman"">,注入250ml "Times New Roman"">容量瓶中,用水稀釋至標(biāo)線,搖勻。此溶液1mL "Times New Roman"">含0.04mg "Times New Roman"">氯離子。?
5.8 硝酸汞標(biāo)準(zhǔn)滴定溶液[C mso-hansi-font-family:"Times New Roman"">(Hg "Times New Roman"">(NO3)2 mso-hansi-font-family:"Times New Roman"">)=0.001mol/L]?
Tc1—硝酸汞標(biāo)準(zhǔn)滴定溶液對氯離子的滴定度,單位為毫克每毫升(mg/mL mso-hansi-font-family:"Times New Roman"">); V2 "Times New Roman"">—標(biāo)定時消耗硝酸汞標(biāo)準(zhǔn)滴定溶液的體積,單位為毫升(mL "Times New Roman"">); V1—空白試驗(yàn)消耗硝酸汞標(biāo)準(zhǔn)滴定溶液的體積,單位為毫升(mL mso-hansi-font-family:"Times New Roman"">); 0.04 "Times New Roman"">—氯離子標(biāo)準(zhǔn)溶液的濃度,單位為毫克每毫升(mg/mL "Times New Roman"">); 5.00 "Times New Roman"">—加入氯離子標(biāo)準(zhǔn)溶液的體積,單位為毫升(mL "Times New Roman"">)。
5.9 硝酸汞標(biāo)準(zhǔn)滴定溶液[C mso-hansi-font-family:"Times New Roman"">(Hg "Times New Roman"">(NO3)2 mso-hansi-font-family:"Times New Roman"">)=0.005mol/L]
5.10 硝酸銀溶液5g/L? "Times New Roman"">將5g硝酸銀(AgNO3 mso-hansi-font-family:"Times New Roman"">)溶于1L "Times New Roman"">水中。 5.11 "Times New Roman"">溴酚藍(lán)指示劑溶液(1g/l "Times New Roman"">)? mso-hansi-font-family:"Times New Roman"">將0.1g "Times New Roman"">溴酚藍(lán)溶于100 mL "Times New Roman"">乙醇(1-4)中。 5.12 mso-hansi-font-family:"Times New Roman"">二苯偶氮碳酰肼溶液(10g/L "Times New Roman"">)? mso-hansi-font-family:"Times New Roman"">將1g "Times New Roman"">二苯偶氮碳酰肼溶于100mL "Times New Roman"">乙醇(5.3)中。
6、儀器與設(shè)備
6.1 天平 "Times New Roman"">精確至0.0001g "Times New Roman"">。
6.2 玻璃容量器皿? "Times New Roman"">滴定管、容量瓶、移液管、稱量瓶。
6.3 測氯蒸餾裝置。