公司基本資料信息
|
mso-hansi-font-family:"Times New Roman"">一、適用范圍:
mso-hansi-font-family:"Times New Roman"">測定碎石、礫石及破碎礫石中軟弱顆粒含量。按顆粒大小分別加以0.15kN mso-hansi-font-family:"Times New Roman"">、0.25kN "Times New Roman"">、0.34kN "Times New Roman"">之荷載,破裂之顆粒即屬于軟弱顆粒,將其棄去,稱出未破裂顆粒的質(zhì)量。
mso-hansi-font-family:"Times New Roman"">二、集料軟弱顆粒試驗機技術(shù)參數(shù):
1、電源電壓:220V
2、最大載荷:1200N
3、分度值:1N
mso-hansi-font-family:"Times New Roman"">三、試驗方法:
mso-hansi-font-family:"Times New Roman"">稱風(fēng)干試樣2 "Times New Roman"">㎏(m1),如顆粒粒徑大于31.5 mso-hansi-font-family:"Times New Roman"">㎜,則稱4 "Times New Roman"">㎏,過篩分成4.75 "Times New Roman"">㎜~9.5㎜,9.5 mso-hansi-font-family:"Times New Roman"">㎜~16 "Times New Roman"">㎜、16㎜以上各1 mso-hansi-font-family:"Times New Roman"">份;將每份中每一個顆粒大面朝下穩(wěn)定平放在壓力機平臺中心,按顆粒大小分別加以0.15kN mso-hansi-font-family:"Times New Roman"">、0.25kN "Times New Roman"">、0.34kN "Times New Roman"">荷載,破裂之顆粒即屬于軟弱顆粒,將其棄去,稱出未破裂顆粒的質(zhì)量(m2) "Times New Roman"">。
mso-hansi-font-family:"Times New Roman"">四、集料軟弱顆粒試驗機計算公式:
mso-hansi-font-family:"Times New Roman"">按式(T0320-1) "Times New Roman"">計算軟弱顆粒含量,精確至0.1% "Times New Roman"">。
P= ×100??????????????????????? (T0320-1)
mso-hansi-font-family:"Times New Roman"">式中:P "Times New Roman"">——粗集料的軟弱顆粒含量(%) "Times New Roman"">;??
m1——各粒級顆??傎|(zhì)量(g) mso-hansi-font-family:"Times New Roman"">;
m2——試驗后各粒級完好顆??傎|(zhì)量(g) mso-hansi-font-family:"Times New Roman"">。
mso-hansi-font-family:"Times New Roman"">五、儀表使用方法:
mso-hansi-font-family:"Times New Roman"">(1 "Times New Roman"">)電源安裝:把電源適配器輸入端插在AC220V "Times New Roman"">(或AC110V "Times New Roman"">)插座上,輸出端插頭插在儀表盒右側(cè)插座上,并打開電源開關(guān),是否通電。
mso-hansi-font-family:"Times New Roman"">(2 "Times New Roman"">)開機:打開電源開關(guān),開機時出現(xiàn)開機畫面,并隨即轉(zhuǎn)為“0.00 "Times New Roman"">”,此時可進行稱重。如開機不為“0.00 "Times New Roman"">”可按“置零”鍵進行清零,待顯示“0.00 "Times New Roman"">”和右下角“”不閃動時進行稱重。
mso-hansi-font-family:"Times New Roman"">(3 "Times New Roman"">)選擇:設(shè)有牛頓(KN "Times New Roman"">)和英鎊(1b "Times New Roman"">)兩種重量單位,按下“轉(zhuǎn)換”鍵,液晶屏右上角“??? ”指向選擇的重量單位。
mso-hansi-font-family:"Times New Roman"">(4 "Times New Roman"">)試驗:液晶屏顯示“0.00 "Times New Roman"">”時可進行試驗。
mso-hansi-font-family:"Times New Roman"">(5 "Times New Roman"">)鎖定:按下“鎖定”鍵可將重量鎖定,此時重量不變化,以便記錄。反復(fù)按“鎖定”鍵將在鎖定和釋放間轉(zhuǎn)換。
mso-hansi-font-family:"Times New Roman"">(6 "Times New Roman"">)超重:稱重超過最大稱量時,將顯示“OF "Times New Roman"">”,并發(fā)出連續(xù)警報聲。出現(xiàn)超重請移去承重面板上的重物,以保護傳感器不致?lián)p壞。
mso-hansi-font-family:"Times New Roman"">(7 "Times New Roman"">)置零:試驗前將裝集料的圓盤放上后,可按“置零”鍵清零后進行壓力試驗。移去試桶后,將顯示負(fù)的皮重,可按“置零”鍵恢復(fù)零位。
mso-hansi-font-family:"Times New Roman"">(8 "Times New Roman"">)出錯指示:秤顯示“Er "Times New Roman"">”,表示出錯,需重新稱重或?qū)Τ舆M行修理。
mso-hansi-font-family:"Times New Roman"">(9 "Times New Roman"">)關(guān)機:關(guān)掉電源開關(guān)。較長時間不用時,請拔掉電源適配器。